BMK3.0LN GWB

AERCO's Benchmark Boiler is designed for condensing application in any closed loop hydronic system. It delivers unmatched burner modulation to match energy input directly to fluctuating system loads to yield the highest possible seasonal efficiency. And no other product packs as much capacity into such a small footprint.

To minimize emissions, the Benchmark Series is fitted with a low NOx burner whose emissions will meet the most stringent NOx and CO requirements. The fully modulating burner also maintains AERCO standards for energy efficiency, longevity, reliability and construction quality.

The Benchmark Series comes standard with AERCO’s Patent Pending, Oxygen Level (O2) monitoring system. This monitoring system, designed to display the O2 level directly on the unit in real time, can also be remotely monitored via Modbus giving the customer the ability to measure the emissions level and fuel economy of the boiler without traditional combustion calibration devices. Benchmark boilers can be used as an individual unit or in modular arrangements and offers selectable modes of operation. In addition to controlling the boiler according to a constant set point, indoor/outdoor reset schedule or 4-20mA signal, one or more units can be integrated via Modbus communications protocol. For boiler plants ranging from 2-8 boilers, AERCO’S built-in Boiler Management Sequencer* can be utilized. For heating plants greater than 8 boilers, the ACS (AERCO Control System) provides the right solution. Likewise, Benchmark systems can be easily integrated with a facility-wide Energy Management or Building Automation System.

FEATURES AND BENEFITS

  • Now, even the largest hydronic projects will be able to cost effectively leverage the fuel savings and operating reliability of a condensing, fully modulating boiler backed by a market-proven design.
  • Unmatched 15:1 Turndown & Low NOx
  • Compact, Easy-to-Apply Design
  • Performance-Proven Design
  • Standard Controls Package

Low NOx Emissions

As a condensing boiler, the thermal efficiency of the BMK3000 increases when applied in a system that leverages cold return water temperatures. But it's the unit's unmatched 15:1 turndown that really maximizes operating efficiency and seasonal fuel savings.

From 200,000 BTU/hr. to its full fire input capacity of 3 million BTU/hr., the BMK3000 precisely matches fluctuating loads. This incredible range of operation minimizes boiler cycling and eliminates wasteful temperature overshoot. And the operating efficiency of the BMK3000 boiler actually increases as the load decreases. In simple terms, at its lowest firing rates (or BTU/hr. inputs), the unit's heat exchanger becomes greatly oversized in proportion to the load - allowing much greater thermal transfer to take place. The means that the BMK3000 saves the most energy during part load operations that characterize the majority of the heating season.

And the BMK Series consistently delivers <30ppm NOx at all firing levels making it ideal for environmentally-friendly projects. The unit employs the same Low NOx burner design and proprietary fuel delivery system as the BMK2.0LN.

Compact, Easy-to-Apply Design

Measuring only 78" high x 28" wide x 56" deep, the BMK3000 fits easily through a standard size doorway and occupies a very small footprint. And it fits the most challenging projects as easily as it fits the smallest mechanical rooms.

The BMK3.0 boiler supports sealed combustion, ceiling/sidewall venting and low gas pressure applications. Ideal in low flow applications, the unit operates with a small water side pressure drop and can withstand no flow conditions without damaging the heat exchanger.

From a controls standpoint, the unit's C-More control system can be integrated directly into a facility-wide Building Automation System via Modbus and is fully compatible with AERCO's Boiler Management System II (BMS II) for multiple unit installations.

Performance-Proven Design

Best of all, the BMK3000 employs the same parts and technologies that have been performance proven over the past ten years as part of the Benchmark 2.0 boiler line. By rearranging interior components, we've increased the unit's capacity by a million BTU/hr. -- but we've only added 8" to the depth of the original product footprint.

The new design employs two, identical, stainless steel, heat exchangers to deliver the extra capacity. Importantly, this is the same heat exchanger design that has been available with the BMK2.0LN for nearly ten years -- same material, same design, same welding, etc. Whereas, competitive product designs often employ primary and secondary heat exchangers made of different materials to cut corners - we've doubled up on quality with the BMK3000.

{tab Standard Controls Package}

The AERCO C-More™ Control Package supports constant set point, remote set point and/or outdoor reset schedule for inpidual boiler operation. Offers step-by-step diagnostic menus and status displays to help users set controls and check faults. More than 40 distinct messages, written in easy-to-understand language, convey subsystem status throughout the start-up sequence and during operation. The flash-upgradeable platform can be remotely monitored, controlled and upgraded via Modbus protocol using the RS-232 or RS-485 connection. The system provides failsafe and independent operation in the event of external building control system failures.

 

Never forget to use the Div - Table converter and the online HTML editor to compose perfect articles for your website!

Customer & Performance